Products
Recent Type B Casks
R75 Datasheet 
Type B (U)
- IAEA certified, UN n° 2916-radioactive wastes in Type B (U) cask; by road-ADR
- Currently in production (2011—2012)
Application
Activated and contaminated PWR reactor and control rod guide tubes
- Designed to transport 1 to 5 control rod guide tubes, either 900, 1300 or
1450 MWe
- Internal basket adapts to all PWR types
- Vertical loading/unloading, cavity full of water
- Ideal when analysis or replacement of control rod guide tubes matters
Specifications
Materials and mechanics
- Stainless steel 304L, stripped and passivated for stabilization
- Equipped with draining, rinsing, drying system & platform for vertical use
- High tech individual damping system complies with dynamic impact requirement
Overall Dimensions
- Length: 5,600 mm (18.7 ft)
- Diameter: 2,100 mm (7.0 ft)
Useful Loading Dimensions
- Length: 4,490 mm (15.0 ft)
- Diameter: 880 mm (2.9 ft)
Weight
- Gross weight: 23,800 kg (52,450 lb)
- Maximum load: 1,700 kg (3,755 lb)
Activity
- Maximum activity: 10 TBq
- Maximum γ activity: 10 TBq (Co60 equivalent)
- Maximum thermal power: 50 W